						SPECIFICATIONS
					 | 
			
				| 
						MODEL
					 | 
						7480 
					 | 
			
				| 
						Output Rating
					 | 
						5KVAC/200mA 
					 | 
			
				| 
						AC WITHSTAND VOLTAGE 
					 | 
			
				| 
						 
					 | 
						Range
					 | 
						Resolution
					 | 
						Accuracy
					 | 
			
				| 
						Output Voltage, ACV
					 | 
						0 - 5000
					 | 
						10
					 | 
						±(2% of setting + 10V)
					 | 
			
				| 
						Output Frequency
					 | 
						50Hz/60Hz ± 0.1%, User Selection
					 | 
			
				| 
						Output Waveform
					 | 
						Sine Wave ,THD.<2% (Resistive Load), Crest Factor = 1.3 - 1.5
					 | 
			
				| 
						Output Regulation
					 | 
						± (1% of output + 10V), From no load to full load
					 | 
			
				| 
						SETTINGS
					 | 
			
				| 
						Hi / Lo -Limit 
					 
						AC Current, mA
					 | 
						0.00 - 99.99/
					 
						100.0 - 200.0
					 | 
						0.01/0.1
					 | 
						±(2% of setting + 2counts)
					 | 
			
				| 
						Ramp Up Time, second
					 | 
						0.1 - 999.9
					 | 
						0.1
					 | 
						±(0.1% + 0.05sec)
					 | 
			
				| 
						HI and LO-Limit (Real), 
					 
						current, mA
					 | 
						0.0 - 999.9
					 | 
						0.1
					 | 
			
				| 
						Dwell Time
					 | 
						0, 
					 
						0.3 - 999.9 sec
					 
						(0=continuous)
					 | 
						0.1
					 | 
			
				| 
						0, 
					 
						0.1 - 999.9 min
					 
						(0=continuous)
					 | 
						0.1
					 | 
			
				| 
						0, 0.1 - 999.9 hr
					 
						(0=continuous)
					 | 
						0.1
					 | 
			
				| 
						Arc Detection
					 | 
						1 - 9 Ranges(9 is the most sensitivity)
					 | 
			
				| 
						AC Current Offset, mA
					 | 
						0 - 2.000 or Auto Set
					 | 
			
				| 
						MEASUREMENT
					 | 
			
				| 
						AC Voltage, KV
					 | 
						0 - 5.00
					 | 
						0.01
					 | 
						±(2% of reading + 2counts)
					 | 
			
				| 
						AC Current, mA
					 | 
						0.00-20.00
					 | 
						0.01
					 | 
						±(2% of reading + 3counts)
					 | 
			
				| 
						20.1-200.0
					 | 
						0.1
					 | 
			
				| 
						GENERAL
					 | 
			
				| 
						Input Voltage AC
					 | 
						230VAC ± 10% , 50/60Hz
					 
						(Input 110V has to add Transformer Box)
					 | 
			
				| 
						PLC Remote Control
					 | 
						Input : Test , Reset , Memory1.2.3 ,Interlock
					 | 
			
				| 
						Output : Pass , Fail , Processing
					 | 
			
				| 
						External Scanner Poert
					 | 
						Build-in only one Scanner Port to connect 7006 Matrix Scanner.
					 | 
			
				| 
						Safety
					 | 
						Smart-GFI Function (<1mA)
					 | 
			
				| 
						Memory
					 | 
						50 memories
					 | 
			
				| 
						Display
					 | 
						20*2 LCD with back light
					 | 
			
				| 
						Key Lock
					 | 
						To prevent unauthorized alteration of the test Parameters
					 | 
			
				| 
						Calibration
					 | 
						Build-in software and external calibrated meters
					 | 
			
				| 
						Interface
					 | 
						RS232 (Option)
					 | 
			
				| 
						Alarm Volume Setting
					 | 
						10 ranges set by the numeric keys on the front panel
					 | 
			
				| 
						Environment
					 | 
						0-40℃, 20-80%RH
					 | 
			
				| 
						Dimension
					 | 
						430mm(W)×133mm(H)×500mm(D)
					 | 
			
				| 
						Net Weight
					 | 
						24.4Kg
					 | 
			
				| 
						STANDARD ACCESSORIES
					 | 
			
				| 
						Power Cord
					 | 
						×1
					 | 
			
				| 
						Fuses
					 | 
						×2 (Including a spare contained in the fuse holder)
					 | 
			
				| 
						Interlock Disable Key
					 
						(1505)
					 | 
						×1
					 | 
			
				| 
						Hipot Return Lead
					 | 
						×1
					 | 
			
				| 
						Hipot Test Lead
					 | 
						×1
					 |